NucleoCounter SP-100

Highest accuracy in sperm cell counting

Chemometec - NucleoCounter SP-100

Main features

  • No interference of gel particles in the semen
  • No interference of egg yolk or milk in the diluent
  • Easy to handle
  • Analysis time: 30 seconds
Chemo metec
Contador de Células Espermales NucleoCounter® SP 100™

Design and Usability

The NucleoCounter® SP-100™ Sperm Cell Counter offers a unique ease of use for the effective determination of total sperm concentration and sperm viability in an ejaculate or extended dose semen sample.

The NucleoCounter® SP-100™ is very easy to operate and measurements can be performed by operators with minimal technical training. It is a compact instrument that fits perfectly in any research, quality control or production site.

The measuring range of the NucleoCounter® SP-100™ is virtually unlimited due to the pre-analysis dilution.

Main characteristics:

  • Easy handling
  • 30 seconds analysis time
  • No cleaning or calibration
  • Excellent reproducibility
  • No interference of gel particles in the semen
  • No interference of egg yolk or milk in the diluent

Determination of cell viability in sperm cell samples

The NucleoCounter® SP-100™ concept offers the determination of cell viability in addition to the total cell count in the sperm sample. The determination of viability is based on the “PI staining” method.

Solutions provided by the team

More features:

Measuring sperm cell viability

Cell Viability (membrane integrity) can be measured with the NucleoCounter® SP-100™ in a two-step procedure by measuring the difference between the total cell count and the non-viable cell count (see figure below).

When a sample is diluted with S100 Reagent, lysis of the viable cell membrane occurs, rendering all cell nuclei susceptible to propidium iodide (PI) staining, resulting in a total cell count.

However, nonviable cells diluted with PBS (phosphate buffered saline) are permeabilized without treatment and therefore stain directly with PI, resulting in a nonviable cell count. The difference between the two measurements gives the viable cell count – or % viability.

Aggregated Cells SP100

Chemometec - NucleoCounter SP-100

Highest accuracy in sperm cell counting

Specifications table.

Product Number 900-0100
Loading volume Approx. 60 μl is loaded into the SP1-Cassette™.
Measuring volume 1 μl in the measuring chamber of the SP1-Cassette™.
Analysis Time Total Count= 30 seconds. Non Viable Count: 80 seconds
Size 38 x 26 x 22 cm (W x H x D)
Weight 3 kg / 6.7 lb
Software SemenView™ documentation and presentation software included
Printer Optional external printer
See everything

Other Brands Represented

Quality control technology from leading brands

Dickey-john
Serstech
OCEAM INSIGHT

Own products and developments

Quality control solutions

InLab NIR-Plus

InLab NIR-Plus

The fastest and most representative Automatic NIR Spectrophotometer for whole grains and coarse granules on the market.
Fluid NIR-Plus

Fluid NIR-Plus

Simplicity, industrial design, speed and precision: The Fluid NIR-Plus simplifies your measurements on fluids.
GRAIN-Q

GRAIN-Q

Grain-Q is the first real-time, geo-referenced NIR device for combine harvesters in Latin America. Make decisions directly from the field.
NIREx

NIREx

When you need versatility and work on a wide variety of products, the NIREx is undoubtedly your best option.
OLSEN-NIR

OLSEN-NIR

OLSEN-NIR is the solution for your continuous measurements on your process line. Learn more about our On-Line custom designs.
T-SCANNER

T-SCANNER

The only NIR device in the world integrated to the operation of automatic calibrators for trucks and wagons. International patent pending.

Contáctenos y conózcanos personalmente.