The volume-calibrated, single-use Via1 Cassette™ and Via2 Cassette™ are a true all-in-one solution. and single-use, they are a true “all-in-one” solution. for an optimized cell count. Your plastic unit The disposable contains the fluorescent dyes used for analysis. A cell sample can be loaded into the cassettes by simply immersing the built-in pipette into the cell suspension in the cell suspension and pressing the piston downwards.
Via1 Cassette™ and Via2 Cassette™ function as single-use pipettes with pre-filled dyes, simplifying the way to obtain the cell sample, mix it with the dyes, and load the sample into the cell counter: All to eliminate operator bias. Pressing the piston creates a vacuum that draws the sample into the staining channels of the cells without the usual pipetting errors, optimizing the accuracy of the process.
The Via1 Cassette™ and Via2 Cassette™ Mixing Channels are preloaded with acridine orange for total cell staining and DAPI for non-viable cell staining. The special design of the channels ensures a uniform mixing of cells and dyes, entering a homogeneous sample into the measuring chamber.
NucleoCounter® NC-200™, NC-202™ and NC-3000™ analyze a total volume of 1.4 µl of sample (1.35 µl for NC-202™) stained with the fluorescent dyes acridine orange and DAPI. The large volume increases accuracy compared to manual counting, where the standard is to count 100 cells regardless of cell concentration and number of squares counted, or to count 0.4 µl volume regardless of the number of cells counted.
Via1-Cassette™ and Via2-Cassette™ are individually calibrated. are individually calibrated and and coded for exact volume control of the exact volume control of the measurement. In a hemocytometer space can vary by up to 10-50%, leading to up to 10-50%, leading to inaccurate concentration inaccurate estimates of cell concentration. concentration.
Many cell counting methods, whether automatic or manual, use trypan blue to stain and identify dead cells. This dye is toxic, and potentially exposes the cell counting operator while pipetting and manipulating the cell sample. The Via-Cassette is preloaded with acridine orange (AO) and DAPI to stain all cells and dead cells, respectively. In addition, it is a custom-made disposable plastic device designed for optimal sample handling and safe disposal. The sample and dyes are contained in the Via-Cassette and will not be released during use. It can be disposed of safely after use, providing a safe working environment for the user.
Please refer to
Via-Cassette’s Declaration of Conformity
for more details
Via1-Cassette™ | Via2-Cassette™ | |
Use with | NucleoCounter® NC-200™ y NucleoCounter® NC-3000™ |
* NucleoCounter® NC-202™ |
Dyes | AO and DAPI | AO and DAPI |
Sample loading volume | 60 µl | 60 µl |
Analysis Volume | 1.4 µl | 1.35 µl |
Calibrated cassette volume | Yes | Yes |
Quality control technology from leading brands
Quality control solutions